High flow and fast switching ISO valves using Ceramic technology for long life operation (in excess of 100,000,000 operations).
Subbase, if required, must be ordered separately.
Air pilot operated valves (mftrs list no ending -70) can be manually overridden via a 6mm hole in the end cap. Another version (list no ending -60) is also available which has no manual override facility.
Two coils and cable plugs are required per valve (one for sol/spring version) and must be ordered separately.
Solenoid valves are fitted with a non locking manual override.
Solenoid valves are suitable for internal or external pilot. They are supplied configured for internal pilot. When the solenoid is fitted I visible on the red seal = Internal, X = External pilot.
5/3 valves are available with closed centre (CC), Open centre (OC), or pressurised centre (PC).