General purpose air line filter from Hankison for removal of liquid water and oil. Removes solid particles to 1 micron (less than or equal to 1.0mg/m3).
This filter is designed to be used in the following situations:
*Upstream of ultra high efficiency oil removal filters
*Downstream of pressure-swing (heatless) dessicant dryers
*At point-of-use if aftercooler/separator is installed upstream
Features Two Stage Filtration as follows:
First Stage - captures larger particles with alternate layers of fibre media and media screen.
Second Stage - coalesces aerosols and captures solid particles with multiple layers of epoxy bonded, blended fibre media.
These filters conform to ISO Quality Standard 8573-1:1995. Please refer to the attached data sheet for a full explanation.
To find the maximum flow at pressures other than 7 bar, please consult the pressure correction table at the end of the attached datasheet.
All filters are supplied with a differential pressure gauge. Automatic drains are included up to F17-B-PF only.
Filters are available with connection sizes of 1/4" BSP to 3" BSP and DN 80 to DN 150 flange.
Element(s) is(are) included with the filter. Larger filters require more than one element.
To order spare elements please use the link below and the part number and qty shown. For example: PF06-1 x 1 means 1 off element part number PF06-1 is required for this filter.
This range supersedes HF7 filter from Hankison which has been discontinued (March 2010).
A modular connection kit for joining two filters and a wall mounting bracket can be ordered separately.