Single phase pressure switch with high control over cut in and cut out pressure differential.
First the cut out pressure must be set by adjusting the screw on the switch.
The cut in pressure can now be set by adjusting the hex nut on the switch.
Some examples of pressure differential below
When the cut out pressure is set to 2 bar, the cut in pressure can be set from 0.3 bar to 1 bar.
When the cut out pressure is set to 4 bar, the cut in pressure can be set from 0.3 bar to 2.8 bar.
When the cut out pressure is set to 6 bar, the cut in pressure can be set from 0.3 bar to 4.6 bar.
When the cut out pressure is set to 8 bar, the cut in pressure can be set from 0.3 bar to 6.5 bar.
When the cut out pressure is set to 10 bar, the cut in pressure can be set from 1.5 bar to 8.5 bar.
When the cut out pressure is set to 12 bar, the cut in pressure can be set from 3.6 bar to 10.3 bar.
For other pressures please see graph in the datasheet.